Sycamore Networks

DNX-88 Multiservice Cross-Connect

Affordable Scalability to Hundreds of T1/E1 Ports

Model Number

  • MKT-006-04353: XNM Expansion Node Manager (Front)
  • MKT-006-02016: XNM Expansion Node Manager (Rear) is an SMC-II (Rear)
  • MKT-006-04115: XCC Expansion Cross-Connect (Front)
  • MKT-006-04015: XCC Expansion Cross-Connect (Rear)
  • MKT-006-04215: XLC Expansion Link Controller (Front)

Mechanical Chassis

  • Can be configured with 2 to 8 Chassis, accommodating up to 86 Application Modules
  • Midplane Architecture with Front Application Modules and Rear Interface Modules

Dimensions

  • 431.8 mm W x 355.6 mm D x 266.7 mm H (17" x 14" x 105.");6 RU height

Weight

  • 25 lbs. per Chassis (empty)

Equipment Floor Loading

  • 26.7 lbs./sq. ft. per Chassis

Equipment Heat Dissipation (AC)

  • 175 Watts, Fully Populated Unit will Generate approx. 27 Watts/sq. ft., Surface Temperatures Measured at 27.6°C per Chassis

Equipment Heat Dissipation (DC)

  • 240 Watts per Chassis

Power

  • MKT-006-11048: DC Input: 48 Vdc 10%, 6 Amps, 288 Watts (Required for Both Inputs to Support Redundancy) Redundancy Optional per Chassis
  • MKT-006-11206: AC Input: 100 to 240 VAC, 47-63 Hz, 3 Amps, 300 Watts (Required for Both Inputs to Support Redundancy) Redundancy Optional per Chassis

Switching Capacity

  • 1.2 Gbps Non-blocking TDM buss

Overcurrent Protection

  • 15 Amp Circuit Breaker

Mounting

  • Rack Mount (19" or 23")

Environment

  • 0° (32°F) to 50°C (122°F) Temperature
  • 0% to 90% Humidity (Non-Condensing)

Compliance

  • CB Safety Report, CE, CSA, FCC, IC ICES-003, NEBS Level 3, UL

Product Information