Solutions Overview
Mobile Operators
Fixed Line Operators
MSO/Cable Operators
Government Networks
Utility Networks
Product Overview
Optical Switching
Edge to Core Optical Switching
SILVX Network Management
Design and Analysis
Network Access
Multiservice Cross-Connects
Multiservice Access Platforms
Access Gateways
ENvision Network Management
DNX-88 Multiservice Cross-Connect
Affordable Scalability to Hundreds of T1/E1 Ports
Model Number
- MKT-006-04353: XNM Expansion Node Manager (Front)
- MKT-006-02016: XNM Expansion Node Manager (Rear) is an SMC-II (Rear)
- MKT-006-04115: XCC Expansion Cross-Connect (Front)
- MKT-006-04015: XCC Expansion Cross-Connect (Rear)
- MKT-006-04215: XLC Expansion Link Controller (Front)
Mechanical Chassis
- Can be configured with 2 to 8 Chassis, accommodating up to 86 Application Modules
- Midplane Architecture with Front Application Modules and Rear Interface Modules
Dimensions
- 431.8 mm W x 355.6 mm D x 266.7 mm H (17" x 14" x 105.");6 RU height
Weight
- 25 lbs. per Chassis (empty)
Equipment Floor Loading
- 26.7 lbs./sq. ft. per Chassis
Equipment Heat Dissipation (AC)
- 175 Watts, Fully Populated Unit will Generate approx. 27 Watts/sq. ft., Surface Temperatures Measured at 27.6°C per Chassis
Equipment Heat Dissipation (DC)
- 240 Watts per Chassis
Power
- MKT-006-11048: DC Input: 48 Vdc 10%, 6 Amps, 288 Watts (Required for Both Inputs to Support Redundancy) Redundancy Optional per Chassis
- MKT-006-11206: AC Input: 100 to 240 VAC, 47-63 Hz, 3 Amps, 300 Watts (Required for Both Inputs to Support Redundancy) Redundancy Optional per Chassis
Switching Capacity
- 1.2 Gbps Non-blocking TDM buss
Overcurrent Protection
- 15 Amp Circuit Breaker
Mounting
- Rack Mount (19" or 23")
Environment
- 0° (32°F) to 50°C (122°F) Temperature
- 0% to 90% Humidity (Non-Condensing)
Compliance
- CB Safety Report, CE, CSA, FCC, IC ICES-003, NEBS Level 3, UL